FEATURE
|
DESCRIPTION
|
Tracking Accuracy
|
Normally more than 10% of receive 3 dB beam width RMS, in Step track mode.
|
Position Encoding
|
Single-speed, brushless resolves and 16-bit track type RDC integrated circuit (IC), Accuracy≤0.05°RMS.
|
Display Resolution
|
0.01°
|
Position Encoding Repeatability
|
Typically 1 LSB of resolver-to-digital conversion resolution
|
Input Power Requirements
|
Drive Unit: 380V AC, three-phase, 50-60Hz, 5 cores. Power depending on the configuration of the drive motor.
ACU: 220V AC, 50-60Hz, 100VA (Normal), Other power supply standard optional, can be declared in the orders.
|
Power Range
|
1/2~20HP (Depending on the antenna diameter)
|
ACU & Tracking Receiver Interface
|
Analog(standard): Single -5~5 VDC analog input;
0~10VDC analog input optional, to be declared in the orders
|
Remote Communication Interface
|
Remote control RS-232/485 serial port, or Ethernet interface options, to be declared in the orders.
|
System Cable
|
ACU / Drive unit interface; RVVP0.3 mm2×10
Resolver / ACU: RVVP 6×0.3 mm2
Motor: YZ 0.7 mm2×3 (depending on motor power)
Limit: RVV0.3 mm2×3
Standard system includes a 30-meter-long cable, up to 100 meters, to be declared in the orders
|
Environmental
|
ACU: Temperature -45°C ~ 65°C; 90% humidity non-condensing
ADU: Temperature -55°C ~ 85°C (-45°C to have low-temperature heating equipment, optional); 100% non-condensing humidity.
|